Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 205
Filter
1.
Europace ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696701

ABSTRACT

BACKGROUND AND AIMS: Women have been historically underrepresented in implantable cardioverter defibrillator (ICD) trials. No data on sex differences regarding subcutaneous-ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS: Consecutive patients enrolled in the multicenter, international i-SUSI registry were analyzed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. RESULTS: A total of 1698 patients were extracted from the iSUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analyzed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs 81.3%, p = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4%vs1.7%; log-rank p = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs 5.8%; log-rank p = 0.595) and inappropriate shocks (rate/year: 4.3%vs3.1%; log-rank p = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, p = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device related-complications.

2.
Heart Rhythm ; 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38493989

ABSTRACT

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

3.
Int J Cardiol Heart Vasc ; 51: 101371, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38435380

ABSTRACT

Background: This study aimed to investigate the characteristics and outcomes of patients diagnosed with Brugada syndrome (BrS) who underwent implantable loop recorder (ILR) insertion during routine clinical activity. Methods: We conducted a comprehensive screening of all consecutive patients diagnosed with BrS at our institution. We analyzed baseline clinical characteristics, arrhythmic findings, and outcomes. Results: Out of 147 BrS patients, 42 (29 %) received an ILR, 13 (9 %) underwent implantable cardioverter-defibrillator (ICD) placement, and 92 patients (63 %) continued regular cardiological follow-up. Patients who received an ILR had a higher prevalence of suspected arrhythmic syncope (43 % vs. 22 %, p = 0.012) and tended to be younger (median age 38 years, interquartile range 30-52, vs. 43 years, 35-55, p = 0.044) with a higher presence of SCN5A gene mutations (17 % vs. 6 %, p = 0.066) compared to those who continued regular follow-up. Additionally, compared to patients with an ICD, those with an ILR had a significantly lower frequency of positive programmed ventricular stimulation (0 % vs. 91 %, p < 0.001). During a median follow-up period of 14.7 months (4.7-44.8), no deaths occurred among the patients with ILR. Eight individuals (19 %) were diagnosed with arrhythmic findings through continuous ILR monitoring, primarily atrial fibrillation, and asystolic pauses. The median time from insertion to the occurrence of these events was 8.7 months (3.6-46.4). No adverse events related to ILR were reported. Conclusion: Continuous monitoring with ILR may facilitate the timely detection of non-malignant rhythm disorders in BrS patients with risk factors but without an indication for primary prevention ICD implantation.

4.
Pacing Clin Electrophysiol ; 47(3): 417-428, 2024 03.
Article in English | MEDLINE | ID: mdl-38375940

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common heart rhythm disorder that is associated with an increased risk of stroke and heart failure (HF). Initially, an association between AF and ion channel dysfunction was identified, classifying the pathology as a predominantly electrical disease. More recently it has been recognized that fibrosis and structural atrial remodeling play a driving role in the development of this arrhythmia also in these cases. PURPOSE: Understanding the role of fibrosis in genetic determined AF could be important to better comprise the pathophysiology of this arrhythmia and to refine its management also in nongenetic forms. In this review we analyze genetic and epigenetic mechanisms responsible for AF and their link with atrial fibrosis, then we will consider analogies with the pathophysiological mechanism in nongenetic AF, and discuss consequent therapeutic options.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Atrial Fibrillation/complications , Heart Atria , Fibrosis , Ion Channels/genetics , Ion Channels/therapeutic use
5.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38246594

ABSTRACT

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Cardiomyopathy, Dilated , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/therapy , Registries , Treatment Outcome
7.
J Interv Card Electrophysiol ; 67(3): 439-441, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38099975

ABSTRACT

ESC Guidelines don't recommend ICD implantation within 40 days after MI, on the basis of old evidence with several limitations. However, a significant number of patients remain at high risk of arrhythmic death also in the early period after ACS, in these patients early ICD implantation or LifeVest may be use with benefit on survival.


Subject(s)
Defibrillators, Implantable , Myocardial Infarction , Humans , Myocardial Infarction/therapy , Time Factors , Death, Sudden, Cardiac/prevention & control
8.
G Ital Cardiol (Rome) ; 24(7): 551-570, 2023 Jul.
Article in Italian | MEDLINE | ID: mdl-37392121

ABSTRACT

The number of cardiac implantable electronic device (CIED) implantations has increased over recent years as a result of population growth, increasing life expectancy, adoption of guidelines, and better access to healthcare. Device-related infection is, however, one of the most serious complications of CIED therapy associated with significant morbidity, mortality, and financial healthcare burden. Although many preventive strategies such as administration of intravenous antibiotic therapy before implantation are well recognized, uncertainties still exist about other regimens. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. The key aspect to successful treatment of definite CIED infections is complete removal of all parts of the system and transvenous hardware, including the device and all leads. Thus, transvenous lead extraction has been increasing. Expert consensus statements on how to prevent, diagnose, and treat CIED infections and on lead extraction have been published by the European Heart Rhythm Association in 2020 and 2018, respectively. The aim of this AIAC position paper is to describe the current knowledge on the risks for device-related infections and to assist healthcare professionals in their clinical decision making regarding its prevention, diagnosis, and management by providing the latest update of the most effective strategies.


Subject(s)
Heart Diseases , Heart , Humans , Anti-Bacterial Agents/therapeutic use , Clinical Decision-Making , Electronics
9.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37481220

ABSTRACT

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

10.
Pacing Clin Electrophysiol ; 46(7): 674-683, 2023 07.
Article in English | MEDLINE | ID: mdl-37279193

ABSTRACT

INTRODUCTION: Permanent His bundle pacing (HBP) is the most physiological pacing modality, and new implantation systems are now available. The aim of the present study was to describe and compare four different techniques to perform HBP. METHODS AND RESULTS: We included all consecutive patients who underwent a HBP attempt in our initial experience between June 2020 and May 2022. The success and characteristics of the procedure were compared among four implantation techniques: the Biotronik Selectra 3D sheath with Solia S60 lead (Selectra 3D), the Boston Scientific Site Selective Pacing Catheter with Ingevity lead (SSPC), the Abbott steerable stylet locator with Tendril lead (Locator), and the use of a standard stylet manually pre-shaped with a conventional pacing lead (Curved stylet). Ninety-eight patients (median age 79 years [interquartile range, 73-83], 83% men) were identified. The Selectra 3D technique was used in 43 procedures, SSPC in 26, Locator in 18 and Curved stylet in 11. The groups had similar clinical characteristics. Overall, procedural success was achieved in 91 patients (93%) with similar proportions among groups (p = .986). Fluoroscopy and procedural times were 6.0 (4.4-8.5) and 60 (45-75) min, respectively, without significant differences (p = .333 and p = .790). The rate of selective capture, the pacing threshold, and the paced QRS duration were also comparable. There was one pre-discharge HBP lead dislodgment (1%) that required implant revision. CONCLUSION: In our experience, four techniques for HBP achieved comparable results in terms of safety and effectiveness. The availability of different systems may lead to widespread use of physiological pacing.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Male , Humans , Aged , Female , Cardiac Pacing, Artificial/methods , Treatment Outcome , Cardiac Catheterization , Retrospective Studies , Electrocardiography/methods
11.
Acta Cardiol ; 78(9): 992-999, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37318077

ABSTRACT

BACKGROUND: A complex transvenous lead extraction (TLE) procedure could be associated with lower success and higher complication rates in inexperienced hands. In this study, we aim to assess the factors that determine procedural difficulty in TLE. METHODS: We retrospectively studied 200 consecutive patients undergoing TLE in a single referral centre from June 2020 to December 2021. Lead extraction difficulty was assessed by the success of simple manual traction with or without a locking stylet, the need for advanced extraction tools and the number of tools required to extract the lead. Logistic and linear regression analyses were used to determine the factors independently affecting these 3 parameters. RESULTS: 363 leads were extracted from 200 patients (79% males, mean age 66.85 years). The indication for TLE was device-related infection in 51.5%. Multivariate analysis revealed the lead indwelling time to be the only factor affecting the 3 parameters of difficulty. Passive fixation leads and dual coil leads increased procedural difficulty by affecting 2 parameters each. Factors that affected one parameter included infected leads, coronary sinus leads, older age of the patient and a history of valvular heart disease, all associated with a simpler procedure. Right ventricular leads were associated with a more complex one. CONCLUSION: The most important factor that increased TLE procedural difficulty was a longer lead indwelling time, followed by passive fixation and dual-coil leads. Other contributing factors were the presence of infection, coronary sinus leads, older patients, a history of valvular heart disease and right ventricular leads.

12.
Ann Thorac Surg ; 116(6): 1292-1299, 2023 12.
Article in English | MEDLINE | ID: mdl-37150272

ABSTRACT

BACKGROUND: Antiarrhythmic drugs and transcatheter ablation in atrial fibrillation (AF) provide suboptimal rhythm control with a not negligible rate of failure in paroxysmal AF (PAF) and nonparoxysmal AF (n-PAF) at midterm and long-term follow-up. This study evaluated the safety profile and long-term efficacy of thoracoscopic ablation in patients with lone AF. METHODS: A consecutive 153 patients with lone AF were prospectively enrolled and underwent thoracoscopic surgical ablation. Inclusion criteria were symptomatic AF refractory to pharmacologic therapy (Vaughan-Williams class I-III), age >18 years, and absence of left atrial thrombosis. Exclusion criteria were long-standing AF >5 years, left atrial diameter >55 mm, and contraindication to oral anticoagulation. The "box lesion set" (encircling of pulmonary veins) was always used. Exclusion of the left atrial appendage was performed only in selected cases. The primary study end point was freedom from AF. Secondary end points were overall survival and cumulative incidence function of cardiac event-related death, cerebrovascular accidents, and pacemaker implantation. RESULTS: There was no in-hospital mortality. Early postoperative complications were pacemaker implantation (4/153 [2.6%]), cerebrovascular accident (2/153 [1.3%]) with full recovery of both, and bleeding requiring surgical revision (2/153 [1.3%]). Overall freedom from AF at 7 years was 86% ± 4% (76.9% in n-PAF, 96.1% in PAF). Survival freedom from AF in patients without antiarrhythmic drugs in PAF and n-PAF groups was 79.1% and 52.2%, respectively. CONCLUSIONS: Thoracoscopic surgical ablation of lone AF by means of an isolated left atrial box lesion provided an excellent long-term rhythm outcome, even in long-standing persistent AF. The isolated left atrial ablation showed an excellent safety profile with low incidence of pacemaker implantation and postoperative complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Adolescent , Atrial Fibrillation/surgery , Treatment Outcome , Follow-Up Studies , Anti-Arrhythmia Agents/therapeutic use , Thoracoscopy , Neoplasm Recurrence, Local/surgery , Postoperative Complications/surgery , Pulmonary Veins/surgery , Recurrence
14.
Int J Cardiol ; 378: 32-38, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36841289

ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) has shown a safe and efficacy profile in the intraoperative and short-term setting; however, data on long-term outcomes are limited. OBJECTIVE: The purpose of this study was to assess long-term outcomes and prognostic factors in patients who underwent TLE. METHODS: Consecutive patients with cardiac implantable electronic device (CIED) who underwent TLE between 2014 and 2016 were retrospectively studied. The primary outcome was the composite endpoint of death and repeated TLE stratified by infective/non-infective indication. Individual components of the primary outcome were also evaluated. RESULTS: One hundred ninety-one patients were included in the analysis, 50% extracted for CIED-related infection. Complete procedural success was achieved in 189 patients (99%) with no major acute complications. After a median of 6.5 years, infection indication was associated with significantly lower event-free survival (67% vs. 83% non-infection group, adjusted hazard ratio [aHR] 1.97, 95% confidence interval [CI] 1.02-3.81, p = 0.04). All-cause mortality rate was higher in the TLE infection group (30% vs. 10%, p < 0.01). The rate of repeated TLE did not differ between groups (4% vs. 7%, p = 0.62). Among patients who had TLE for infection, the presence of vegetation (aHR 2.56; 95%CI 1.17-5.63, p = 0.02) and positive blood cultures (aHR 2.64; 95%CI 1.04-6.70, p = 0.04) were independently associated with the primary outcome. CONCLUSION: Patients who underwent TLE for CIED-related infection exhibit a high mortality risk during long-term follow-up. Vegetation and positive blood cultures in patients with CIED-related infection are associated with a worse prognosis regardless of successful and uncomplicated TLE.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Retrospective Studies , Tertiary Care Centers , Device Removal , Pacemaker, Artificial/adverse effects , Treatment Outcome
15.
Int J Antimicrob Agents ; 61(3): 106734, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36690123

ABSTRACT

BACKGROUND: Infections of cardiovascular implantable electronic devices (CIED) are mainly due to Gram-positive bacteria (GPB). Data about Gram-negative bacteria CIED (GNB-CIED) infections are limited. This study aimed to investigate risk factors, clinical and diagnostic characteristics, and outcome of patients with GNB-CIED. METHODS: A multicentre, international, retrospective, case-control-control study was performed on patients undergoing CIED implantation from 2015 to 2019 in 17 centres across Europe. For each patient diagnosed with GNB-CIED, one matching control with GPB-CIED infection and two matching controls without infection were selected. RESULTS: A total of 236 patients were enrolled: 59 with GNB-CIED infection, 59 with GPB-CIED infection and 118 without infection. No between-group differences were found regarding clinical presentation, diagnostic and therapeutic management. A trend toward a higher rate of fluorodeoxyglucose positron emission computed tomography (FDG PET/CT) positivity was observed among patients with GNB than in those with GPB-CIED infection (85.7% vs. 66.7%; P = 0.208). Risk factors for GNB-CIED infection were Charlson Comorbidity Index Score (relative risk reduction, RRR = 1.211; P = 0.011), obesity (RRR = 5.122; P = 0.008), ventricular-pacing ventricular-sensing inhibited-response pacemaker implantation (RRR = 3.027; P = 0.006) and right subclavian vein site of implantation (RRR = 5.014; P = 0.004). At 180-day survival analysis, GNB-CIED infection was associated with increased mortality risk (HR = 1.842; P = 0.067). CONCLUSIONS: Obesity, high number of comorbidities and right subclavian vein implantation site were associated with increased risk of GNB-CIED infection. A prompt therapeutic intervention that may be guided using FDG PET/CT is suggested in patients with GNB-CIED infection, considering the poorer outcome observed in this group.


Subject(s)
Cardiovascular Infections , Defibrillators, Implantable , Gram-Negative Bacterial Infections , Prosthesis-Related Infections , Humans , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography/adverse effects , Positron Emission Tomography Computed Tomography/methods , Defibrillators, Implantable/adverse effects , Defibrillators, Implantable/microbiology , Retrospective Studies , Radiopharmaceuticals , Risk Factors , Gram-Negative Bacterial Infections/epidemiology , Gram-Negative Bacterial Infections/complications , Obesity , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/diagnosis
17.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Article in English | MEDLINE | ID: mdl-36709469

ABSTRACT

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Subject(s)
Arrhythmias, Cardiac , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/therapy , Electric Impedance , Retrospective Studies , Ventricular Fibrillation , Defibrillators, Implantable
18.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Article in English | MEDLINE | ID: mdl-36496135

ABSTRACT

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Subject(s)
Pacemaker, Artificial , Humans , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Registries , Equipment Design
19.
Pacing Clin Electrophysiol ; 46(1): 39-43, 2023 01.
Article in English | MEDLINE | ID: mdl-35941725

ABSTRACT

Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures. LPI reports in DC patients are scarce. We report a case of LPI in a DC+SVI patient, followed by a brief but comprehensive literature review.


Subject(s)
Dextrocardia , Pacemaker, Artificial , Situs Inversus , Humans , Dextrocardia/complications , Situs Inversus/complications , Situs Inversus/therapy
20.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36115442

ABSTRACT

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Subject(s)
Pacemaker, Artificial , Humans , Middle Aged , Treatment Outcome , Equipment Design , Pacemaker, Artificial/adverse effects , Time Factors , Cardiac Pacing, Artificial/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...